Medical Ultrasound Imaging
Thursday, 21 November 2024
• Welcome to
     Medical-Ultrasound-Imaging.com!
     • Sign in / Create account
 
 'Second' p6
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Second' found in 50 articles
1
term [
] - 49 definitions [
]
Result Pages :
...
...
Harmonic Imaging
Harmonic imaging relies on detection of harmonics of the transmitted frequency produced by bubble oscillation. This method is widely available on ultrasound scanners and uses the same array transducers as conventional imaging. A major limitation of the use of ultrasound contrast agents is the problem that signals from the microbubbles are mixed with those from tissue. Echoes from solid tissue and red blood cells are suppressed by harmonic imaging.
In harmonic mode, the system transmits at one frequency, but is tuned to receive echoes preferentially at double that frequency, and the second harmonic echoes from the place of the bubble. Typically, the transmit frequency lies between 1.5 and 3 MHz and the receive frequency is selected by means of a bandpass filter whose center frequency lies between 3 and 6 MHz.
Color Doppler and real-time harmonic spectral Doppler modes have also been implemented and show a level of tissue motion suppression not available in conventional modes.

See also Harmonic B-Mode Imaging, and Harmonic Power Doppler.
Harmonic Power Doppler
(HPD) Harmonic power Doppler is currently one of the most sensitive techniques for detecting ultrasound contrast agents. HPD works by transmitting multiple pulses toward the object to be imaged and detecting the pulse-to-pulse changes in the received echo signals.
Second harmonic bandbass filtering is applied to the received signals to exploit the non-linear behavior of scattering from bubbles (clutter). Harmonic power Doppler operates best at high output levels because of increased contrast destruction, and pulse amplitudes close to the maximum allowed are used much of the time.
With a high mechanical index, non-linear propagation of the sound will cause significant harmonic components from tissue, and the contrast agent to tissue ratio will decrease.
Also called Harmonic Power Angio. See also Multiple Frame Trigger.
Hertz
(Hz) The standard SI unit of frequency.
Definition: The number of repetitions of a periodic process per unit time. It is equal to the old unit cycles or oscillations each second of a simple harmonic motion. The unit is named for the German physicist Heinrich Rudolf Hertz.
Larger units are
kilohertz (kHz) = 1 000 Hz
megahertz (MHz) = 1 000 kHz
gigahertz (GHz) = 1 000 MHz
Intermittent Imaging
Contrast microbubbles can be destroyed by intense ultrasound and the scattered signal level can increase abruptly for a short time during microbubble destruction, resulting in an acoustical flash (sudden increase in echogenicity).
Intermittent imaging with high acoustic output utilizes the properties of contrast microbubbles to improve blood-to-tissue image contrast by imaging intermittently at very low frame rates.
The frame rate is usually reduced to about one frame per second, or it is synchronized with cardiac cycles so that enough contrast microbubbles can flow into the imaging site where most microbubbles have been destroyed by the previous acoustic pulse. Because bubbles are destroyed by ultrasound, controlling the delay time between frames produces images whose contrast emphasizes regions with rapid blood flow rate or regions with high or low blood volume.
LOGIQ 5
gehealthcare.com/usen/ultrasound/genimg/products/logiq5/index.html From GE Healthcare.;
Versatile High Performance System 'The LOGIQ 5 Expert ultrasound system delivers the premium performance advantage of TruScan architecture in a versatile high performance package. Advanced capabilities for outstanding clinical performance are available with the efficiency and productivity needed to meet clinical demands.'
Device Information and Specification
CONFIGURATION
Normal system
IMAGING OPTIONS
Coded excitation, B-flow, anatomical M-mode, virtualconvex, automatic optimization
OPTIONAL PACKAGE
3-D Digital processing and manipulation, DICOM 3.0 capable, plus VetPACS all digital interfacing
STORAGE, CONNECTIVITY, OS
On-board patient, image and reporting archive, HDD, CD-ROM disk burner included, PCMCIA, USB, Windows-based OS
DATA PROCESSING
Exclusive raw data digital acquisition and storage, 150+ frames per second truedigital imaging, all digital video clip and still image capture (4,000)
H*W*D m (inch.)
1.45 * 0.52 * 0.99 (57 * 20 * 39)
WEIGHT
180 kg (397 lbs.)
POWER CONSUMPTION
less than 1.5 KVA
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]