SONOLINE Sienna™
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-1&catalogId=-1&catTree=100001%2C12805%2C12761&level=0&productId=17280 From Siemens Medical Systems;
'This extremely flexible system supports targeted applications for OB/GYN, Radiology, Internal Medicine, Urology, and Prostate Brachytherapy. The large transducer selection, most with high-frequency capabilities, provides the right tool for general imaging, radiology, and internal medicine applications.'
Device Information and Specification
CONFIGURATION
Mobile, compact
SCAN MODES
DISPLAY MODES
Color flow, Power Doppler imaging, Transparent Energy Mode Imaging
Broadband, high-fidelity, multi-frequency, linear and curved
2.5 to 12.0 MHz
PROBE PORTS
Two - four
MEASUREMENT/CALCULATION FUNCTIONS
OB/GYN measurements and report package, off-line analysis
OPTIONAL PACKAGE
IMAGE PROCESSING
Zero Loss Flow Processing, 63-frame CINE Review with up to 63 B-mode frames and 31 color frames
IMAGE STORAGE/TRANSMISSION
Storage of patient report for archiving, reviewing, and editing, optional digital archive manager or digital network manager
Transurethral Sonography
Transurethral echography or sonography is used to detect small tumors of the urinary bladder or to visualize the urethra and surrounding muscles with special transducers. The bladder neck can be visualized using a transrectal probe.
In addition, high intensity focused ultrasound provides treatment of benign prostatic hyperplasia and adenocarcinoma of the prostate. Small catheter-based sectored tubular or planar transducers with highly directional energy deposition and rotational control are used for precise treatment. Regions of the prostate can be selective coagulatet while monitoring and controlling the treatment with MRI.

See also Urologic Ultrasound, Lithotripsy, Reflux Sonography, Ultrasound Therapy, Interventional Ultrasound and Thermotherapy.
Transvaginal Sonography
(TVS) The transvaginal sonography (transvaginal echography or endovaginal ultrasound), uses a small vaginal transducer (5-7.5 MHz) that is inserted into the vagina to depict the inner female organs (uterus, ovaries, vessels). As a general rule, ultrasound works better when the probe is close to the area being examined. Compared with a sonogram through the abdominal wall, the transvaginal technique produces a sharper image, not only because of the close proximity to the uterus, but also because the better signal to noise ratio of the used transducer.

Indications:
detection and delineation of pelvic masses;
ectopic pregnancy;
ovarian cysts or tumors;
pelvic inflammatory disease;
bladder and rectal tumors.

The advantage of transvaginal sonography is being able to get very close to the structures of the pelvis, and thus get better images and a more reliable diagnosis.

See also Pelvic Ultrasound, Hysterosalpingo Contrast Sonography.
Venous Ultrasound
Peripheral veins are easily tested using a 5 to 10 MHz transducer. The venous walls are smooth, thin, and compressible. Venous ultrasound imaging requires the compression of the veins in the transverse view. If compression is performed in the longitudinal view, the vein may roll away from the transducer possibly creating a false-negative examination.
The lumen of the normal vein is echo free. Increasing the gain will display low level echoes representing venous blood moving towards the heart. When performing Doppler spectral analysis or color Doppler the gate should be placed in the center of the vessel. In case of a non-obstructing or recanalized thrombosis, the Doppler gate should be placed within the remaining vessel lumen for flow detection.

See also Maximum Venous Outflow and Zero Offset.
Veterinary Ultrasound
Conventional, CT and MR imaging technologies are limited in their availability, to depict soft tissue, or to show dynamic activity, like cardiac muscle contractility and blood flow. Easy applicability, real-time sonography and biopsy facilitation are important advantages in veterinarian medicine. Veterinary ultrasound has a very high sensitivity to show the composition of soft tissues, but the low specificity is a disadvantage. High ultrasound system performance includes Doppler techniques, contrast enhanced ultrasound, 3D ultrasound, and tissue harmonic imaging to improve resolution.
Technical and physical requirements of veterinary ultrasound are the same as in human ultrasonography. The higher the sound frequency, the better the possible resolution, but the poorer the tissue penetration. Image quality is depended of the ultrasound equipment. For example, a 10 MHz transducer is excellent for imaging of superficial structures; a 3.5 or 5.0 megahertz transducer allows sufficient penetration to see inner structures like the liver or the heart. In addition, the preparation and performing of the examination is similar to that of humans. The sound beam penetrates soft tissue and fat well, but gas and bone impede the ultrasonic power. Fluid filled organs like the bladder are often used as an acoustic window, and an ultrasound gel is used to conduct the sound beam.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2025 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2025-04-05 02:38:00]