Partial Volume Artifact
A partial volume artifact is caused by the size of the image voxel. The loss of resolution is caused by multiple features present in the image voxel. In ultrasound imaging that occurs when the slice thickness is wider than the scanned structure. This artifact is also called slice thickness artifact or volume averaging artifact.

See also Ultrasound Picture.
Pediatric Ultrasound
Ultrasound is the ideal tool to examine children of all ages. It is fast, painless, uses no ionizing radiation, and does not require a baby to remain still for long periods. Real-time modes show movement of internal tissues and organs. Advanced ultrasound imaging techniques such as color Doppler, 4D ultrasound, harmonic imaging, and higher resolution, as well as the application of ultrasound contrast agents broaden the potential of ultrasound.
Pediatric [paediatric, Brit.] ultrasound can be used in all body regions and reduce the number of more invasive or radiating examinations that often additionally need sedation or intravenous iodinated contrast agents.

See also Fetal Ultrasound, Reflux Sonography, Ultrasound Safety, Abdominal Ultrasound and Pregnancy Ultrasound.
Persistence
The persistence of microbubbles is depended of the shell stability and the density of the gas.
This is defined by the equation:
(R x d)/(DIFS x constsat)
where R is the bubble radius, d the gas density, DIFS the gas diffusivity and constsat the saturation constant.
Microbubbles are stabilized with thin coatings of substances such as palmitic acid or by encapsulation in microspheres made with albumin, lipids, or polymers. Low-solubility low-diffusibility gases dramatically improve the persistence. Most recently developed ultrasound contrast agents combine these two approaches to prolong contrast enhancement.
Persistence is also a type of temporal smoothing used in both gray scale and color Doppler imaging. Successive frames are averaged as they are displayed to reduce the variations in the image between frames, hence lowering the temporal resolution of the image.
Pixel
The pixel is a picture element. Pixels do not have a fixed size; their diameters are generally measured in micrometers (microns). Although the pixel is not a unit of measurement itself, pixels are often used to measure the resolution (or sharpness) of images.
QB-Mode
QB-mode (Quadratic Brightness-mode) images are gray scale images from the quadratic component. QB-mode achieves higher contrast and increased dynamic range than the standard B-mode ultrasound images, without loss in spatial resolution.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2025 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]