Real-Time Transducer
Transducers used for the real-time mode are different than for the A-mode, B-, or M-modes. A linear array transducer with multiple piezoelectric crystal elements that are different arranged and fired, transmits the needed larger sound beam.
A subgroup of x adjacent elements (8-16; or more in wide-aperture designs) is pulsed simultaneously; the inner elements pulse delayed with respect to the outer elements. The interference of the x small divergent wavelets generates a focused beam. The delay time determining the focus depth of a real-time transducer can be changed during imaging.
Similar delay factors applied during the receiving phase, result in a dynamic focusing effect on the return. This forms a single scan line in the real-time image. To produce the following scan line, another group of x elements is selected by shifting one element position along the transducer array from the previous group. This pattern is then repeated for the groups along the array, in a sequential and repetitive way.
Receiver
The Receiver is the component of the ultrasound machine that receives the current generated in the transducer from the returning sound waves.

See also Blanking Distance, and Range Gating.
Rectangular Array Transducer
The elements of a rectangular array transducer (also called matrix transducer) are arranged in a rectangular pattern. Rectangular arrays with unequal rows (e.g. 3, 5, 7) of transducer elements are in real 2D (two-dimensional), but they are termed 1.5D, because the number of rows is much less than the number of columns. Their main advantage is electronic focusing even in the elevation plane (z-plane).
The transducers that are termed 2D have an equal number of rows and columns. 2D transducers have the potential to provide real-time 3D ultrasound imaging without moving the transducer.
Active matrix array transducers have several elements in the short axis and in addition multiple elements along the long axis. This allows electronic focusing in both axes, resulting in a narrower elevation axis beam width in the near field and far field.

SONOACE 8000 SE
www.medison.com/eng/pd/general/sa8000se/info.asp From Medison Co.,Ltd.;
'The SONOACE 8000 SE is designed to deliver exceptional imaging performance across the entire range of diagnostic applications. Advanced imaging technologies make SONOACE 8000 SE a particularly outstanding choice for your application.'

SONOACE 8000 Special Edition
www.medison.com/eng/pd/diagnostic/solidus_live/info.asp From Medison Co.,Ltd.;
'SONOACE 8000 Special Edition, continuing on the outstanding reputation of the earlier SONOACE 8000 line of systems, offers the unmatched features and image quality for its price range. Headlined by the latest digital multi-beam processing technology and excellent system specifications, this new system will produce images that are not only best in class but images from higher-class systems.'

Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]