'Power Doppler' p5 Searchterm 'Power Doppler' found in 34 articles 4 terms [ • ] - 30 definitions [• ] Result Pages : •
From GE Healthcare.;
'The System of Choice for General Imaging Imagine a leading-edge ultrasound system so versatile that it can meet the demands of virtually any clinical setting. With the LOGIQ® 9, you'll have a high-performance system capable of multi-dimensional imaging for a full range of clinical applications - from abdominal to breast to vascular imaging. And an ergonomic design that improves scanning comfort and clinical work flow. Now, imagine what LOGIQ® 9 could do for you and your patients.'
Device Information and Specification
APPLICATIONS
Abdominal, cardiac, breast, intraoperative, musculoskeletal, neonatal, OB/GYN, orthopedic, pediatric, small parts, transcranial, urologic, vascular
CONFIGURATION
17' high resolution non-interlaced flat CRT, 4 active probe ports
B-mode, M-mode, coded harmonic imaging, color flow mode (CFM), power Doppler imaging (PDI), PW-HPRF, CW Doppler, color Doppler, pulsed wave Doppler, tissue harmonic imaging
IMAGING OPTIONS
CrossXBeam spatial compounding, coded ultrasound acquisition), speckle reduction imaging (SRI), TruScan technology store raw data, real-time 4D ultrasound, Tru 3D ultrasound
STORAGE, CONNECTIVITY, OS
Patient and image archive, HDD, DICOM 3.0, CD/DVD, MOD, PCMCIA, USB, Windows-based
DATA PROCESSING
Digital beamformer with 1024 system processing channel technology
H*W*D m (inch.)
1.62 * 0.61 * 0.99 (64 * 24 * 39)
WEIGHT
202 kg (408 lb.)
POWER CONSUMPTION
less than 2 KVA
•
From Bayer Schering Pharma AG:
Available in Europe since 1996 and in Japan since 1999. Currently, the marketing situation is unclear. Levovist® is a first generation USCA consisting of galactose (milk sugar) ground into tiny crystals whose irregular surfaces act as nidation sites on which air pockets form when it is suspended in water, much as soda water bubbles form at small irregularities on the surface of the glass. A trace of palmitic acid is added as a surfactant to stabilize the resultant microbubbles. When Levovist® dissolves in blood, air trapped inside the galactose is released as free gas bubbles. These bubbles have a weak encapsulating shell and are easily destroyed by ultrasound. Different contrast ultrasonography methods have been developed since the introduction of Levovist®. Initially, Levovist® was an echo contrast medium for improving sensitivity in color Doppler and Power Doppler examinations, but was found to suffer from significant blooming, making it difficult to observe small blood vessels. However, Levovist® improves the accuracy of echocardiographic examinations in such indications as assessment of left ventricular function. In addition to their vascular phase, some ultrasound contrast agents (USCAs) can exhibit a tissue- or organ-specific phase. Levovist® can accumulate within the liver and the spleen for up to 20 min once it has disappeared from the blood pool and improves the detectability of focal liver lesions and allows more reliable control of interventional tumor treatments. Varied types of information can be obtained by applying contrast imaging at different times after the injection using Levovist® in both the arterial phase and the late organ-specific phase. 1 g Levovist® granules contain 999 mg D-galactose and 1 mg palmitic acid. Brand names in other countries: Levovist/Levograf
Drug Information and Specification
RESEARCH NAME
SHU 508A
DEVELOPER
INDICATION
APPLICATION
Intravenous injection
TYPE
Microbubble
Galactose/Palmitic acid
CHARGE
Negative
Air
MICROBUBBLE SIZE
95% < 10μm
PRESENTATION
Vials of 2.5 g and 4.0 g incl. one plastic ampoule containing 20 ml water for injection, one mini-spike and one disposable syringe of 20 ml
STORAGE
Room temp 15−30°C
PREPARATION
Reconstitute with 5 to 17 ml water
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT! •
From ESAOTE S.p.A.; 'Megas CVX is your fully digital beamformer ultrasound system with phased, linear, convex and annular array technology. The modern modularity offers basic B-Mode, PW-CW Doppler, CFM and Power Doppler, TEI™-Tissue Enhancement Imaging and CnTI™- Contrast Tuned Imaging™.' •
The multiple frame trigger adjusts the acquisition of a series of consecutive frames, usually with ECG triggering. Multiple frame triggers are used in harmonic power Doppler modes to identify motion artifacts in contrast enhanced Doppler imaging.
•
(RI) The resistive index is a measure of resistance to arterial flow and is calculated from the power Doppler arterial waveform. The equation of this index is: RI = (peak systolic velocity - end diastolic velocity) : peak systolic velocity Result Pages : |