CTS-5000
www.siui.com/english/product/5000.htm

From SIUI Inc.;
'A breakthrough in traditional designation
The latest technologies and processes
Closely combined with up-to-date IT technology
A variety of advanced ultrasound imaging technologies
The best solution provided for users'

'CTS-5000 can match a variety of super high density, super broadband, multi-frequency probes, including convex, micro-convex, linear, vaginal, rectal probes etc., which are widely used to different clinical diagnosis such as abdominal (liver, kidney, gall-bladder, pancreas), gynecology (uterus, ovary), obstetrics (early pregnancy, basic obstetrics, multi gestation, fetal echo), cardiology (adult and pediatric cardiology), small parts (thyroid, galactophore, testicles), peripheral vascular, prostate.'

Device Information and Specification
APPLICATIONS
CONFIGURATION
Normal system, gray scale(256)
Linear and convex
PROBES STANDARD
1 * Super broadband convex probe;; 1* high frequency linear probe;
2.5MHz ~ 11.0MHz, broad band, tri-frequency
B-mode, 2B, 4B, M-mode, B/M, ZOOM B(real zoom)
IMAGING OPTIONS
Real zoom, max. Zoom * 4.0, multiplying power and position selectable
OPTIONAL PACKAGE
Linear, convex, micro-convex, vaginal, rectal probes; Tri-probe connector; DICOM 3.0 interface and software; ...
H*W*D m
1.30 * 0.52 * 0.77
WEIGHT
90kg (main unit)
POWER REQUIREMENT
AC 220V/110V, 50Hz/60Hz
POWER CONSUMPTION
0.45 KVA
Coded Excitation
Increasing the frequency of the transmitted power improves the image quality of ultrasound, but the improvement in resolution results in a decreased signal to noise ratio (SNR). Higher acoustic power levels can prevent the loss in SNR, but among other reasons, ultrasound regulations limit this to avoid heating or cavitation.
Coded excitation increase the signal to noise ratio without the loss of resolution by using coded waveforms. Coded excitation allows transmitting a long wide-band pulse with more acoustic power and high penetration of the sound beam.
Cross-section Scattering
Cross-section scattering is a measure of the scattering strength of a point scatterer. The scattering strength is dependent on the size of the scatterer, the density and compressibility of the scatterer and the surrounding medium, and the ultrasound wavelength.
If a transducer emits ultrasound with a total acoustic power of P, and the power is assumed to be uniform distributed over the US beam cross-sectional area, then the ultrasound intensity at a certain range, is defined by:
I = P/A
where I is the intensity, and A is the cross-sectional beam area at that range.
A point scatterer located in the ultrasound beam at this range, will scatter the ultrasound with a total acoustic power of Ps, defined by:
Ps = I s
where s is the scattering cross-section of the point scatterer.
Doppler Ultrasound
Doppler ultrasound is a medical imaging technique for calculating the relative velocity between two points by measuring the frequency shift of a sound wave transmitted from one point to the other, based on the Doppler effect. Continuous or pulsed Doppler is frequently used to examine cardiovascular blood flow. The combination of routine 2D-mode and Doppler ultrasound allows a complete evaluation of the heart's anatomy and function (including the fetal heart). See also Doppler Fluximetry in Pregnancy.
Doppler ultrasound depends on the fact that if a moving object reflects the ultrasound waves, the echo frequencies are changed. A higher frequency is created if the object is moving toward the probe//transducer and a lower frequency if it is moving away from it. How much the frequency is changed depends upon how fast the object is moving. Doppler ultrasound shows the different rates of blood flow in different colors on a monitor in real time.
The major Doppler parameters are the peak systolic velocity and the end-diastolic velocity. The peak systolic velocity ratio compensates the variability between different patients and instrumentations.

Different Doppler and duplex techniques:
Hi Vision 5500 - EUB-5500
www.hitachimed.com/products/ultrasound/eub_5500.asp From Hitachi Medical Corporation (HMC), sales, marketing and service in the US by Hitachi Medical Systems America Inc.
The HI VISION™ 5500 - EUB-5500 fully digital ultrasound system delivers the latest generation of signal processing technology, sophisticated transducer design, and a host of features and options for advanced imaging capabilities across a wide range of clinical situations. This system is compatible with all Pentax ultrasound endoscopes.
Device Information and Specification
CONFIGURATION
Compact system
Five frequency (except mini-probes)
RANGE OF PROBE TYPE
Linear, convex, radial, miniradial/miniprobe, biplane, phased array, echoendoscope longitudinal, echoendoscope radial
PROBE FREQUENCIES
Linear: 5.0-13 MHz, convex: 2.5-7.5 MHz, phased: 2.0-7.5 MHz, sector: 2.0-7.5 MHz
IMAGING OPTIONS
3RD generation color artifact suppression
OPTIONAL PACKAGE
3D imaging, dual omni-directional M-mode display, steerable CW Doppler, Pentax EUS and Fujinon Mini-probe
STORAGE, CONNECTIVITY, OS
Patient and image database management system, HDD, FDD, MOD, CD-ROM, Network, DICOM 3.0, Windows XP
DATA PROCESSING
12 bit gigasampling A/D for precise signal reproduction, Quadra beam processing for fast frame rates
H*W*D m (inch.)
1.40 x 0.51 x 0.79 (55 x 20 x 31)
WEIGHT
130 kg (286 lbs.)
POWER CONSUMPTION
1.2kVA
ENVIRONMENTAL IMPACT
4096 btu/hr heat output
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]