Medical Ultrasound Imaging
Sunday, 24 November 2024
• Welcome to
     Medical-Ultrasound-Imaging.com!
     • Sign in / Create account
 
 'Power' p10
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Power' found in 126 articles
11
terms [
] - 115 definitions [
]
Result Pages :
Half-Value Layer
(HVL) The attenuation of ultrasound waves in human tissue is characterized as the half value layer, or the half power distance. Half value layer means the distance the sound beam will travel in a tissue before its amplitude or energy is attenuated to half its original value. Air and lung tissue have extremely short half-power distances and represent severe obstacles to the transmission of acoustic energy.
LOGIQ 5
gehealthcare.com/usen/ultrasound/genimg/products/logiq5/index.html From GE Healthcare.;
Versatile High Performance System 'The LOGIQ 5 Expert ultrasound system delivers the premium performance advantage of TruScan architecture in a versatile high performance package. Advanced capabilities for outstanding clinical performance are available with the efficiency and productivity needed to meet clinical demands.'
Device Information and Specification
CONFIGURATION
Normal system
IMAGING OPTIONS
Coded excitation, B-flow, anatomical M-mode, virtualconvex, automatic optimization
OPTIONAL PACKAGE
3-D Digital processing and manipulation, DICOM 3.0 capable, plus VetPACS all digital interfacing
STORAGE, CONNECTIVITY, OS
On-board patient, image and reporting archive, HDD, CD-ROM disk burner included, PCMCIA, USB, Windows-based OS
DATA PROCESSING
Exclusive raw data digital acquisition and storage, 150+ frames per second truedigital imaging, all digital video clip and still image capture (4,000)
H*W*D m (inch.)
1.45 * 0.52 * 0.99 (57 * 20 * 39)
WEIGHT
180 kg (397 lbs.)
POWER CONSUMPTION
less than 1.5 KVA
LOGIQ® 9
gehealthcare.com/usen/ultrasound/genimg/products/logiq9/index.html From GE Healthcare.;
'The System of Choice for General Imaging
Imagine a leading-edge ultrasound system so versatile that it can meet the demands of virtually any clinical setting. With the LOGIQ® 9, you'll have a high-performance system capable of multi-dimensional imaging for a full range of clinical applications - from abdominal to breast to vascular imaging. And an ergonomic design that improves scanning comfort and clinical work flow. Now, imagine what LOGIQ® 9 could do for you and your patients.'

Device Information and Specification
CONFIGURATION
17' high resolution non-interlaced flat CRT, 4 active probe ports
RANGE OF PROBE TYPE
Multi-frequency, 4D, convex - micro convex, phased array, linear, specialty
IMAGING OPTIONS
CrossXBeam spatial compounding, coded ultrasound acquisition), speckle reduction imaging (SRI), TruScan technology store raw data, real-time 4D ultrasound, Tru 3D ultrasound
STORAGE, CONNECTIVITY, OS
Patient and image archive, HDD, DICOM 3.0, CD/DVD, MOD, PCMCIA, USB, Windows-based
DATA PROCESSING
Digital beamformer with 1024 system processing channel technology
H*W*D m (inch.)
1.62 * 0.61 * 0.99 (64 * 24 * 39)
WEIGHT
202 kg (408 lb.)
POWER CONSUMPTION
less than 2 KVA
Lithotripsy
(ESWL) Extracorporeal shock wave lithotripsy is a special use of kidney ultrasound, where high intensity focused ultrasound pulses are used to break up calcified stones in the kidney, bladder, or urethra. Pulses of sonic waves pulverize dense renal stones, which are then more easily passed through the ureter and out of the body in the urine. The ultrasound energy at high acoustic power levels is focused to a point exactly on the stone requiring an ultrasound scanning gel for maximum acoustic transmission.
Air bubbles in the ultrasound couplant, regardless of their size, degrade the performance of Lithotripsy and have the following effect:
Air bubbles smaller that 1/4 wavelength cause scattering of the sound waves as omni directional scatterers and less acoustic energy reaches the focal point. The result is less acoustic power at the focal point to disintegrate the kidney stone.
Air bubbles larger than 1/4 wavelength act as reflectors and deflects the acoustic energy off in a different direction. These results in less acoustic energy at the focal point.
Microbubbles dispersed throughout the ultrasound couplant layer change the average acoustic impedance of the gel layer (which reduces the total transmitted energy) and, due to refraction, change the focal point.
SD 260
www.medical.philips.com/main/products/ultrasound/general/sd260/ From Philips Medical Systems;
'The powerful system...
The SD 260 is a powerful B/W ultrasound system that offers standard all major scan techniques: curved, linear and annular phased array. The user has a choice of no less than 12 probes and can connect up to three probes simultaneously, regardless of their technique. The SD 260 is perfectly suited for use in either a busy hospital or clinic.'
This product is not available in the US, Australia, or New Zealand from Philips Medical Systems.

Specifications for this system will be available soon.

Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]