(FDA) An agency of the US federal government established by Congress in 1912 and presently part of the US Department of Health and Human Services. The FDA gives classifications of medical devices according to potential risks and controls the safety of marketed drugs. See also Class I II III Devices, Phase 1 2 3 4 Drug Trials and US FDA 510k Document.
Contact Information:
ONLINE
Contact
• View NEWS results for 'Food and Drug Administration' (13). •
From Philips Medical Systems;
'Clinicians are demanding smaller, higher performing systems specifically designed to meet their clinical and operational challenges. The new Philips HD11 system provides an uncompromising platform, plus advanced options in a highly mobile and easy-to-use system.'
Device Information and Specification
APPLICATIONS
Abdominal, cardiac (also for adults with TEE), musculoskeletal (also pediatric), OB/GYN, prostate, smallparts, transcranial, vascular
CONFIGURATION
17' high resolution non-interlaced flat CRT, 4 active probe ports
B-mode, M-mode, coded harmonic imaging, color flow mode (CFM), power Doppler imaging (PDI), color Doppler, pulsed wave Doppler, tissue harmonic imaging
IMAGING OPTIONS
CrossXBeam spatial compounding, coded ultrasound acquisition),speckle reduction imaging (SRI), TruScan technology store raw data, CINE review with 4 speed types
OPTIONAL PACKAGE
Transesophageal scanning, stress echo, tissue velocity imaging (TVI), tissue velocity Doppler (TVD), contrast harmonic imaging
STORAGE, CONNECTIVITY, OS
Patient and image archive, HDD, DICOM 3.0, CD/DVD, MOD, Windows-based
DATA PROCESSING
Digital beamformer with 1024 system processing channel technology
H*W*D m (inch.)
1.62 * 0.61 * 0.99 (64 * 24 * 39)
WEIGHT
246 kg (498 lbs.)
POWER CONSUMPTION
less than 1.5 KVA
•
Huygens principle states that an expanding sphere of waves behaves as if each point on the wave front were a new source of radiation of the same frequency and phase. The principle explains how a flat ultrasound transducer can transmit a narrow ultrasound beam, which in the near field is confined to the dimensions of the transducer surface. Spherical wavelets are emitted from numerous point sources on the transducer surface. They interfere to form a narrow, slightly converging beam of ultrasound in the near field. The wavefronts in the beam are nearly parallel. A precondition for this interference is that the transducer surface is much larger than the ultrasound wavelength. See also Interference Artifact. Further Reading: News & More:
•
Ultrasound contrast agents (USCAs) improve the sensitivity of various ultrasound applications. They usually stay within the vascular space and can be injected several times. Nevertheless the contrast enhancement is limited caused by physiologic clearance and bubble destruction. Different injection techniques to improve the imaging:
•
Bolus injection generally results in a more or less prolonged blooming phase and a relatively short enhancing period of approximately 2- to 3 minutes.
•
Slow injection provides markedly prolonged enhancement by minimizing over-contrast artifacts.
•
Continuous perfusion achieves stable and uniform enhancement, lasting until the infusion is stopped.
Continuous infusion yield a steady-state concentration of the USCAs, greater examination time with optimal enhancement, avoid bloom and possibly other artifacts. Continuous infusion also allows the sonographer to optimize the effective dose individually during the examination. See also Power Modulation. Further Reading: News & More: •
From GE Healthcare.;
Versatile High Performance System 'The LOGIQ 5 Expert ultrasound system delivers the premium performance advantage of TruScan architecture in a versatile high performance package. Advanced capabilities for outstanding clinical performance are available with the efficiency and productivity needed to meet clinical demands.'
Device Information and Specification
APPLICATIONS
Abdominal, cardiac, musculoskeletal, neonatal, OB/GYN, small parts, transcranial, urologic, vascular
CONFIGURATION
Normal system
B-mode, M-mode, anatomic M-mode creation and adjustment, triplex, 3D ultrasound, pulsed wave Doppler, continuous wave Doppler, power Doppler, color Doppler, spectral Doppler
IMAGING OPTIONS
OPTIONAL PACKAGE
STORAGE, CONNECTIVITY, OS
On-board patient, image and reporting archive, HDD, CD-ROM disk burner included, PCMCIA, USB, Windows-based OS
DATA PROCESSING
H*W*D m (inch.)
1.45 * 0.52 * 0.99 (57 * 20 * 39)
WEIGHT
180 kg (397 lbs.)
POWER CONSUMPTION
less than 1.5 KVA