'Harmonic' p10 Searchterm 'Harmonic' found in 62 articles 9 terms [ • ] - 53 definitions [• ] Result Pages : •
From Hitachi Medical Corporation (HMC), sales, marketing and service in the US by Hitachi Medical Systems America Inc.
The HI VISION™ 5500 - EUB-5500 fully digital ultrasound system delivers the latest generation of signal processing technology, sophisticated transducer design, and a host of features and options for advanced imaging capabilities across a wide range of clinical situations. This system is compatible with all Pentax ultrasound endoscopes.
Device Information and Specification
APPLICATIONS
Abdominal, brachytherapy/cryotherapy, breast, cardiac, dedicated biopsy, endoscopic, intraoperative, laparoscopic, musculoskeletal, OB/GYN, pediatric, small parts, urologic, vascular
CONFIGURATION
Compact system
Five frequency (except mini-probes)
Linear, convex, radial, miniradial/miniprobe, biplane, phased array, echoendoscope longitudinal, echoendoscope radial
3 modes of dynamic tissue harmonic imaging (dTHI), pulsed wave Doppler, continuous wave Doppler, color flow imaging, power Doppler, directional power Doppler, color flow angiography, real-time Doppler measurements
IMAGING OPTIONS
3RD generation color artifact suppression
OPTIONAL PACKAGE
STORAGE, CONNECTIVITY, OS
Patient and image database management system, HDD, FDD, MOD, CD-ROM, Network, DICOM 3.0, Windows XP
DATA PROCESSING
H*W*D m (inch.)
1.40 x 0.51 x 0.79 (55 x 20 x 31)
WEIGHT
130 kg (286 lbs.)
POWER CONSUMPTION
1.2kVA
ENVIRONMENTAL IMPACT
4096 btu/hr heat output
•
Imagent® is an injectable suspension for intravenous administration during a sonogram. This diagnostic contrast agent for enhancement of ultrasound images contains perflexane lipid microspheres. Imagent® US is indicated in the assessment of heart function and perfusion, as well as the detection of tumors and blood flow abnormalities by using gray scale, color Doppler, and harmonic ultrasound imaging techniques. During the course of its development, the brand name for this product has changed from Imagent to Imavist (between August 2000 and March 2002) back to Imagent. The manufacturer's 06/03/02 press release announcing FDA approval refers to the product as 'Imagent (formerly Imavist),' and the approval notice and monograph posted at the FDA site refers to the product as Imagent. Jointly developed by Alliance Pharmaceutical Corp and Bayer Schering Pharma AG (Germany). Source: PR Newswire - 10/10/96, 03/31/98, 10/13/99, 03/13/01, 10/08/01; FDA approvals - 05/31/02; Alliance Pharmaceutical press release - 06/03/02. Currently the production of Imagent® is discontinued.
Drug Information and Specification
RESEARCH NAME
AF0150
DEVELOPER
IMCOR Pharmaceuticals, Inc.
INDICATION
APPLICATION
Intravenous
TYPE
Lipid: DMPC
CHARGE
Neutral
Perfluorohexane/Nitrogen
MICROBUBBLE SIZE
99.8% < 10μm
PRESENTATION
-
STORAGE
Room Temp 15−30 °C
PREPARATION
Reconstitute with 10 ml water
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT! •
(LVO) Ultrasound contrast agents improve the echocardiography assessment of left ventricular function and the low sensitivity of changes in left ventricular ejection fraction (LVEF). In addition, harmonic imaging techniques and automated border detection (ABD) together with contrast enhanced left ventricular opacification increase endocardial border delineation (EBD) and the results compared to native echocardiography.
Further Reading: Basics:
•
Microbubbles filled with air or inert gases are used as contrast agents in ultrasound imaging. Compression and rarefaction created by an ultrasound wave insonating a gas-filled microbubble along with the mechanical index of the ultrasonic beam lead to volume pulsations of the bubbles, and it is this change that results in the signal enhancement. Microbubbles have diameters from 1 μm to 10 μm and a thin flexible or rigid shell composed of albumin, lipid, or polymer confining a gas such as nitrogen, or a perfluorocarbon. These microbubbles can cross the pulmonary capillaries and have a serum half-life of a few minutes. Microbubbles in the 1-10 μm range have their resonance at the frequencies used in diagnostic ultrasound (1−15MHz). Smaller bubbles resonate at higher frequencies. Caused by this coincidence, they are such effective reflectors. The intrinsic compressibility of microbubbles is approximately 17,000 times more than water, and they are very strong scatterers of ultrasound. Under acoustic pressure the vibrating bubble radius may have a conventional linear response or a harmonic non-linear response. Microbubbles usually increase the Doppler signal amplitude by up to 30 dB. Further Reading: Basics:
News & More:
•
The multiple frame trigger adjusts the acquisition of a series of consecutive frames, usually with ECG triggering. Multiple frame triggers are used in harmonic power Doppler modes to identify motion artifacts in contrast enhanced Doppler imaging.
Result Pages : |