Cineloop
A cineloop is a period of images, stored digitally as a sequence of individual frames. Cineloops recorded at high frame rates may contain more frames than were displayed during the examination.
Coherent Contrast Imaging
(CCI) A major limitation of the use of ultrasound contrast agents is the problem that signals from the microbubbles are mixed with those from tissue, so that the distribution of the microbubbles is not optimally displayed either in Doppler or gray scale.
Coherent contrast imaging is a high frame rate implementation of inverting the phase of alternate sound pulses and summing the resulting echoes. The symmetrical signals from linear reflectors are cancelled leaving those from non-linear scatterers, with the advantage that the cancellation is performed without the need to transmit two pulses per image line so that bubble destruction is minimized. Coherent contrast imaging yields best results in the vascular phase of phospholipid microbubbles (such as Definity and SonoVue).

See also Coherence.
Dwell Time
The dwell time (also called ensemble length or packet size) is the transmitting duration of ultrasonic waves focused at one place or the Doppler samples for each line of sight. The reduction of the dwell time is of use if threshold pressures are exceeded.
The sensitivity to slow flow and accuracy of Doppler measurement increase with longer dwell times. With increased dwell times, the frame rates decrease and the capability of Color Doppler images to depict fast changes in hemodynamics is limited.
FFCardio FCU-2000
www.fukuda.co.jp/fukuda_e/products/fcu-2000.html From Fukuda Denshi Co., Ltd.;
'Ultrasound Scanner with built-in Electrocardiograph
Realizes Diagnostic Ultrasound Imaging and 12-lead ECG examination with one unit
Large 10.4-inch TFT color LCD adopted
Cine memory of maximum 64 frames is available
Four types of Color Scale Imaging facilitate identification of delicate signals
High Frame Rate mode powerfully supports the Cardiovascular region
Image data filing in IC card for data management and for easy comparison with past data
M-mode continuous recording available with 3-ch ECG data from the cine memory
A highly precise and quality printer is integrated
Enhanced 12-lead ECG analysis report provided
Hybrid and compact design ensures space saving'

FFsonic UF-5600
www.fukuda.co.jp/fukuda_e/products/uf-5600.html From Fukuda Denshi Co., Ltd.;
'Operation-friendly Switches and Controls backlit to permit the operator to identify them in a darkroom
Image Optimization through Ultrasonic Frequency Changeover without replacement of the probe
High frame rate enhancement mode for Cardiac echo
Cine memory for selection of best data through SCROLL, LOOP, or MANUAL review
Programmable function keys allow to get predefined for measurement parameters.
Special measurement software usable in a wide range.
Measurement Report page on the display can be printed as required.'

Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]