Coded Excitation
Increasing the frequency of the transmitted power improves the image quality of ultrasound, but the improvement in resolution results in a decreased signal to noise ratio (SNR). Higher acoustic power levels can prevent the loss in SNR, but among other reasons, ultrasound regulations limit this to avoid heating or cavitation.
Coded excitation increase the signal to noise ratio without the loss of resolution by using coded waveforms. Coded excitation allows transmitting a long wide-band pulse with more acoustic power and high penetration of the sound beam.
Image Quality
The perfect image quality is dependent on some assumptions of the propagation of ultrasound waves in tissues after generating in an imaging system. These assumptions are important for the developing of optimal ultrasound imaging systems.
The sound velocity in the examined tissue is homogeneous and constant (around 1540 m/s).
The propagation of ultrasound is straight ahead.
The ultrasound beam is infinite thin in its thickness and lateral direction.
The detected echo comes from the shortest sound path between reflector and transducer.
The ultrasound echo is originated by the last generated sound pulse.
The amplitudes of the echoes are proportional to the difference of the acoustical impedance caused by different tissue layers.
A lot of steps can be taken to prevent artifacts and to improve image quality, for example beamforming is used to focus the ultrasound beam, and contrast agents decrease the reflectivity of the undesired interfaces or increase the backscattered echoes from the desired regions.

See also Coded Excitation, Validation and Refraction Artifact, Q-Value, Ultrasound Phantom, Dead Zone, Narrow Bandwidth.
LOGIQ 5
gehealthcare.com/usen/ultrasound/genimg/products/logiq5/index.html From GE Healthcare.;
Versatile High Performance System 'The LOGIQ 5 Expert ultrasound system delivers the premium performance advantage of TruScan architecture in a versatile high performance package. Advanced capabilities for outstanding clinical performance are available with the efficiency and productivity needed to meet clinical demands.'
Device Information and Specification
CONFIGURATION
Normal system
IMAGING OPTIONS
Coded excitation, B-flow, anatomical M-mode, virtualconvex, automatic optimization
OPTIONAL PACKAGE
3-D Digital processing and manipulation, DICOM 3.0 capable, plus VetPACS all digital interfacing
STORAGE, CONNECTIVITY, OS
On-board patient, image and reporting archive, HDD, CD-ROM disk burner included, PCMCIA, USB, Windows-based OS
DATA PROCESSING
Exclusive raw data digital acquisition and storage, 150+ frames per second truedigital imaging, all digital video clip and still image capture (4,000)
H*W*D m (inch.)
1.45 * 0.52 * 0.99 (57 * 20 * 39)
WEIGHT
180 kg (397 lbs.)
POWER CONSUMPTION
less than 1.5 KVA
Submicron Ultrasound Contrast Agents
Submicron ultrasound contrast agents are gas-filled, double-walled microspheres with a diameter smaller than 1 μm that rupture when exposed to ultrasound energy at megahertz frequencies. These agents differ from traditional ultrasound contrast microbubbles in that the submicron bubbles may serve as extravascular agents. They are small enough to travel through the lymphatic system and to be extravasated from tumor neovasculature. The detection of these agents is limited by their hard shell, which requires high-pressure ultrasound insonation for shell rupture and excitation of the gas bubble. After shell rupture, the gas diffuses rapidly from submicron sized agents. The optimal processing of each echo is important.
Voluson 730 Expert
gehealthcare.com/usen/ultrasound/genimg/products/voluson730/index.html From GE Healthcare.;
'GE is defining a new age of ultrasound. We call it Volume Ultrasound. GE's Voluson 730 Expert is a powerful system that enables real-time techniques for acquiring, navigating and analyzing volumetric images so that you can make clinical decisions with unprecedented confidence.'

Device Information and Specification
CONFIGURATION
15' high resolution non-interlaced flat CRT, 4 active probe ports
RANGE OF PROBE TYPE
Multifrequency, 4D, convex - micro convex, phased array, linear, specialty
IMAGING OPTIONS
CrossXBeam spatial compounding, coded excitation , spatio-temporal image correlation (STIC), B-Flow (simultaneous imaging of tissue and blood flow), strain rate imaging (SRI)
OPTIONAL PACKAGE
STIC angio and color, CrossXBeamCRI, speckle reduction imaging, volume contrast imaging (VCI), inversion mode, volume calculation II, fetal heart analysis capabilities, interactive volume renderings
STORAGE, CONNECTIVITY, OS
SonoView archiving and data management, network, HDD, DICOM 3.0, CD/DVD, MOD, USB, Windows-based
DATA PROCESSING
Digital beamformer with 512 system processing channel technology
H*W*D m (inch.)
1.43 * 0.69 * 1.02 (56 * 27 * 40)
WEIGHT
136 kg (300 lbs.)
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]