B-scan comined with D-scan (D=Depth) is used to avoid image inhomogeneity. Different transmitter signals for each depth are applied and prefiltered pseudoinversely according to the transfer properties of the covering tissue. Pulse compression techniques with nonlinearly frequency modulated signals are used to gain the required energy for inverse filtering. D-scan is a modified C-scan used in nondestructive testing with the display of amplitudes. In the 2D graphical presentation, time of flight values are displayed in the top view on a test surface. See also A-Scan, B-Scan and C-Scan. •
(DAC) Part of the interface that converts digital numbers from the computer into analog (ordinary) voltages or currents. In ultrasound systems e.g., the high voltage transmit amplifiers that drive the transducers might be controlled by digital to analog converters (DACs) to shape the transmit pulses for better energy delivery to the transducer elements.
•
The Doppler interrogation frequency is the frequency of the transmitted acoustic energy relative to the measured Doppler frequency shift. This frequency is most but not necessarily, the nominal transducer frequency. See also Doppler Effect and Doppler Ultrasound. •
Doppler techniques are dependent on the transducers used. The transducer operating in continuous wave mode utilizes one half of the elements and is continuously sending sound energy while the other half is continuously receiving the reflected signals. If the transducer is being used in a pulsed wave mode, the whole transducer is used to send and then receive the returning signals. Pulsed wave techniques allow the accurate measurement of blood flow at a specific area in the heart and the detection of both velocity and direction. Measurement is performed by timing the reception of the returning signals giving a view of flows at specific depths. The region where flow velocities are measured is called the sample volume. Errors in the accuracy of the information arise if the velocities exceed a certain speed. The highest velocity accurately measured is called the Nyquist limit.
•
Continuous Wave Doppler
Used for accurate measurement of high Velocity flow. A disadvantage is the poor range of resolution.
•
Pulsed Wave Doppler
Used for the measurement of velocities at a specific location with a good range of resolution. A disadvantage is the imprecise measuring of high velocities. See also Doppler Velocity Signal and Doppler Effect. ![]() Further Reading: Basics:
News & More:
•
Gray scale [also grayscale, grey scale = brit.] produces basically black and white images with series of shades of gray. Solid areas appear white and fluid areas appear black, varying from black at the weakest intensity to white at the strongest. Gray scale resolves artifacts as small as 1 mm. The display is made by transmitting bursts of energy and analyzing the returning signal. Gray scale pictures are limited to the gray scale tones; color pictures display more information because the color is added to the gray scale. Most ultrasound contrast agents also improve gray scale visualization of the flowing blood to such a degree that the tissue echogenicity increases. Gray scale enhancement of flow in an organ promises to improve lesion detection, along with the ability to differentiate between normal and abnormal areas, using many of the criteria already routinely used in CT and MRI. See also Compress, Densitometry, Triplex Exam and QB-Mode. Result Pages : |