Medical Ultrasound Imaging
Thursday, 21 November 2024
• Welcome to
     Medical-Ultrasound-Imaging.com!
     • Sign in / Create account
 
 'Echocardiography' p3
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Echocardiography' found in 31 articles
7
terms [
] - 24 definitions [
]
Result Pages :
ACUSON Aspen™ Echo
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-11&catalogId=-11&catTree=100001%2C12805%2C12761&level=0&productId=17968 From Siemens Medical Systems;
The new gold standard in echocardiography is defined by Native Tissue Harmonic Imaging (NTHI) and DELTA Differential Echo Amplification−two powerful technologies that were first introduced on Acuson's Sequoia™ echocardiography system. Now they have migrated to the Aspen™ Advanced system.

Specifications for this system will be available soon.

Albunex
Albunex and Infoson, used mainly in cardiac evaluations, are first generation one-pass-only contrast agents and have been replaced by the new-generation contrast media. Albunex and Infoson are the same sonicated human serum albumin microbubbles. Infoson is licensed and manufactured in Europe, while Albunex was produced in the USA.
Albunex, an air-filled microbubble with a denatured albumin shell (modified from air-filled albumin microspheres prepared from sonicated 5% human serum albumin), was the first FDA-approved contrast agent, but is no longer in production.
Cardiac shunts and valve regurgitations are often evaluated with Color Doppler Imaging (CDI), which also improved with injections of Albunex, but this agent is pressure-sensitive and does not recirculate. It is effectively a one-pass-only agent, limiting its clinical efficacy.

See also First generation USCA, Echocardiography and Contrast Enhanced Ultrasound.
Drug Information and Specification
DEVELOPER
INDICATION
Contrast sonography and Doppler-echocardiography
APPLICATION
Intravenous injection
TYPE
Microbubble
SHELL - STABILIZATION
Albumin
Air
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
EchoGen®
EchoGen® is a fluorocarbon-based (dodecafluoropentane) third generation USCA. EchoGen® consists of microbubbles stabilized with surfactants in a phase shift colloid emulsion (perflenapent). EchoGen® requires no preparation, reconstitution, or refrigeration.
Perflenapent emulsion would represent a significant advance in contrast echocardiography caused by effective and long lasting opacification of the left ventricle and enhanced endocardial border delineation.
The persistence of the contrast effect permits interrogation in multiple echocardiographic views, as well as the visualization and localization of myocardial perfusion deficits at rest by producing a negative contrast effect.
October 12, 2000
Sonus Pharmaceuticals, Inc. announced a strategic decision to refocus the Company on the development of its drug delivery and blood substitute products. At the same time, Sonus has withdrawn the NDA (New Drug Application) and discontinued clinical activity for its ultrasound contrast product, EchoGen®.
August 06, 2001
Sonus Pharmaceuticals, Inc. announced that it has entered into an agreement to sell its ultrasound contrast assets for $6.5 million to Amersham plc. As part of the agreement, Sonus has also assigned to Nycomed its interest in the ultrasound contrast patent license agreement entered into with Chugai Pharmaceutical Co. Ltd. and Molecular Biosystems Inc in January 2001.
Drug Information and Specification
RESEARCH NAME
QW3600
INDICATION -
DEVELOPMENT STAGE
APPLICATION
Intravenous
TYPE
Microbubble
-
CHARGE
Negative
Dodecafluoropentane
MICROBUBBLE SIZE
-
PRESENTATION
-
STORAGE
Refrigerate 2−8 °C
PREPARATION
Finished product
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Left Ventricular Opacification
(LVO) Ultrasound contrast agents improve the echocardiography assessment of left ventricular function and the low sensitivity of changes in left ventricular ejection fraction (LVEF). In addition, harmonic imaging techniques and automated border detection (ABD) together with contrast enhanced left ventricular opacification increase endocardial border delineation (EBD) and the results compared to native echocardiography.
ACUSON Cypress™
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-1&catalogId=-1&catTree=100001%2C12805%2C12761&level=0&productId=17970 From Siemens Medical Systems;
We see a way to review 100% of your cardiovascular ultrasound exams and reports anywhere, anytime. The Cypress™ system is a highly miniaturized, all digital, phased array echocardiography system that provides complete studies and outstanding images - even on the most technically difficult patients.

Specifications for this system will be available soon.

Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us