Unlike regular sound, ultrasound can be directed into a single direction. The echoes received by a stationary probe will result in a single dimensional signal showing peaks for every major material change. To generate a 2D picture, the probe is swiveled, either mechanically or through a phased array of ultrasound transducers. The data is analyzed by computer and used to construct the image. In a similar way, 3D pictures can be generated by computer using a specialized probe. In this way, a photo of an unborn baby may be made. Some ultrasonography machines can produce color pictures, of sorts. Doppler ultrasonography is color coded onto a gray scale picture. From the amount of energy in each echo, the difference in acoustic impedance can be calculated and a color is then assigned accordingly. See also Densitometry and 3D Ultrasound. •
Peripheral veins are easily tested using a 5 to 10 MHz transducer. The venous walls are smooth, thin, and compressible. Venous ultrasound imaging requires the compression of the veins in the transverse view. If compression is performed in the longitudinal view, the vein may roll away from the transducer possibly creating a false-negative examination. The lumen of the normal vein is echo free. Increasing the gain will display low level echoes representing venous blood moving towards the heart. When performing Doppler spectral analysis or color Doppler the gate should be placed in the center of the vessel. In case of a non-obstructing or recanalized thrombosis, the Doppler gate should be placed within the remaining vessel lumen for flow detection. See also Maximum Venous Outflow and Zero Offset. Further Reading: News & More:
•
From GE Healthcare.;
'Vivid 7 Dimension, a premier cardiovascular ultrasound system from GE Healthcare, expands on the strength of a powerful imaging platform to offer new, innovative technology of dimensional proportions.'
Device Information and Specification
CONFIGURATION
Multi-frequency, linear, convex, phased, sector
B-mode, C-mode, M-mode (and 2-D), triplex mode, harmonic imaging, color flow mapping, 3D ultrasound display, power Doppler imaging (PDI), color Doppler, pulsed wave Doppler, continuous wave Doppler, tissue velocity imaging (TVI), tissue type imaging (TTI), strain rate imaging (SRI), tissue synchronization imaging (TSI)
IMAGING OPTIONS
CINE review with 5 speed types, bi- andtri-plane imaging with e.g. stress echo and tissue synchronization imaging
STORAGE, CONNECTIVITY, OS
Patient and image archive, HDD, MOD, DVD, USB flash card, DICOM 3.0 Windows-based
DATA PROCESSING
Digital beamformer with 1024 system processing channel technology
H*W*D m (inch.)
1.58 * 0.64 * 0.89 (62 * 25 * 35)
WEIGHT
191 kg (420 lbs.)
POWER CONSUMPTION
less than 2 KVA
•
The 2D-mode (2-Dimensional-mode) is a spatially oriented B-mode (brightness) ultrasound. The imaged structures are displayed 2 dimensional as a function of depth and width. The brightness level is based on the echo signal amplitude. Most of the ultrasound devices in medical imaging are 2D real-time scanner. The image is created by a rapidly back and forth swept sound beam over the region of interest. See also Gray Scale. Further Reading: News & More:
•
From Siemens Medical Systems;
The ACUSON Aspen™ ultrasound system resulted from a unique convergence of select ACUSON Sequoia™ ultrasound system technologies and other ACUSON innovations to form an entirely new imaging platform. Its new digital system architecture provides complete digital control of the ultrasound echoes from the transducer through the captured digital examination. Specifications for this system will be available soon. Result Pages : |