Doppler techniques are dependent on the transducers used. The transducer operating in continuous wave mode utilizes one half of the elements and is continuously sending sound energy while the other half is continuously receiving the reflected signals. If the transducer is being used in a pulsed wave mode, the whole transducer is used to send and then receive the returning signals. Pulsed wave techniques allow the accurate measurement of blood flow at a specific area in the heart and the detection of both velocity and direction. Measurement is performed by timing the reception of the returning signals giving a view of flows at specific depths. The region where flow velocities are measured is called the sample volume. Errors in the accuracy of the information arise if the velocities exceed a certain speed. The highest velocity accurately measured is called the Nyquist limit.
•
Continuous Wave Doppler
Used for accurate measurement of high Velocity flow. A disadvantage is the poor range of resolution.
•
Pulsed Wave Doppler
Used for the measurement of velocities at a specific location with a good range of resolution. A disadvantage is the imprecise measuring of high velocities. See also Doppler Velocity Signal and Doppler Effect. Further Reading: Basics:
News & More:
•
Echo ranging is the ultrasound relationship between transit time and reflector depth expressed as: t = 2d//c •
(EUS) Endoscopic ultrasound uses a small probe that is inserted in the rectum either through a proctoscope or by itself. During the test biopsies of any suspicious areas are possible. The usual necessary preparation is an enema to empty the rectum. Endoscopic ultrasound provides additional information about rectal polyps, rectal cancer, perianal infection, and sphincter muscle injuries and improves the selection of patients for local excision. Transrectal echography using a high-frequency transducer is a well established method for preoperative rectal carcinoma assessment. Endoscopic scanning is limited by the ultrasound physics (depth and axial resolution) of the endocavitary probe. Therefore, the combination of endoscopic and transcutaneous ultrasound is most favorable. •
Enhancement artifacts occur if decreasing of the echo amplitude is not equal with penetration depth caused by inhomogeneous tissue layers and fluids like cysts or air-filled regions. The enhancement artifact appears as a hyperintense (hyperechoic) signal.
The attenuation of the ultrasound wave in fluids is much lower as the attenuation in other tissues, therefore tissues distal to fluid are enhanced. Artificial enhancement may also be found distal to a homogeneous solid tumor surrounded by adipose tissue, due to the comparatively high attenuation in fat. See also Boundary Layer, and Half-Value Layer. •
(F) The number of cycles of a periodic process per unit time. Frequency and wavelength are inversely related. The higher the frequency the smaller the wavelength. The frequency of ultrasound is expressed in units of hertz (Hz), where 1 Hz = 1 cycle per second. The effect of different frequencies on tissue penetration: The higher the frequency the less the penetration, the lower the frequency the greater the penetration. As frequency increases, resolution improves but the imaging depth or penetration decreases. The lower the axial resolution, the more detail can be seen. Usual frequencies for pediatric ultrasound: 5.0mHz to 7.5mHz and 10mHz. Usual frequencies for adult ultrasound: 2.0mHz to 3.0mHz. See also Doppler Interrogation Frequency, Multi-frequency Probe, and Huygens Principle. Result Pages : |