Bubble Destruction
Bubble destruction describes the microbubble shell rupture by ultrasound pulses. The bubble destruction increases with increasing peak negative pressure and decreasing frequency. The mechanical index is an indicator for the effectiveness of microbubble destruction. Contrast enhanced ultrasound relies on bubble rupture to detect bubbles in small vessels.

See also Negative Bolus.
Cerebrovascular Ultrasonography
Cerebrovascular ultrasonography is the best screening tool for the detection of carotid artery stenosis. Transcranial sonography is used in the evaluation of patients with suspected cerebrovascular disease, but a common problem is the attenuation of the ultrasound signal by the skull.
Contrast enhanced ultrasound play a particularly important role in the visualization of the intracranial vessels, and thus improves the accuracy of transcranial Doppler and increases the potential of this technique. The use of microbubbles is helpful for classification of stenosis and for plaque evaluation in patients with poor initial examination. Ultrasound contrast agents avoid misdiagnosing a subtotal stenosis, which is a very important clinical issue.

See also Adventitia, Intima, Periorbital Doppler, and Acoustic Window.
Clutter
Clutters are unwanted components of the received signal. In contrast enhanced ultrasound, clutter often describes the part of the received echo that is not from microbubble contrast agents.

See also Release Burst Imaging.
Contrast Harmonic Imaging
(CHI) Contrast harmonic imaging is an ultrasound technique to improve the measurement of blood perfusion or capillary blood flow. Based on the nonlinear properties of contrast agents, CHI transmits at the fundamental frequency but receives at the second harmonic. Contrast enhanced echo signals contain significant energy components at higher harmonics (bubbles acts as harmonic oscillators), while tissue echoes do not. Caused by that contrast signal can be separated from tissue echoes by the characteristic signal.
In combination with the pulse inversion technique, CHI promises very high contrast agent sensitivity with high spatial resolution.

See also Ultrasound Contrast Agent Safety and Hemoglobin.
Contrast Imaging Techniques
Many different contrast imaging techniques have been developed. Most are either variations, hybrids, or combinations of the following ultrasound techniques:

See also Coherent Contrast Imaging, Ultrasound Picture and Targeted Contrast Imaging.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2025 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]