Medical Ultrasound Imaging
Sunday, 24 November 2024
• Welcome to
     Medical-Ultrasound-Imaging.com!
     • Sign in / Create account
 
 'Contrast Agent' p18
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Contrast Agent' found in 101 articles
8
terms [
] - 93 definitions [
]
Result Pages :
Phospholipid
Phospholipids are a major component of all biological membranes. When placed in water, phospholipids form a bilayer, where the hydrophobic tails line up against each other. This forms a membrane with hydrophilic heads on both sides. This membrane is partially permeable and very flexible.
Phospholipid containing microbubbles are in use as diagnostic ultrasound contrast agents. Phospholipids can be targeted to atheroma and other pathologic components to enhance atherosclerosis imaging. The majority of these echogenic liposomes range in diameter from 0.25 to 5.0 μm.
Power Mode
In power mode the amplitude (power) of color Doppler signals is displayed, regardless of the velocity. Power does not have negative values and is independent of sampling frequency. An aliasing artifact does not occur in power mode images. Caused by plotting the quantity enhanced by echo contrast agents in a power map, power mode is often used in contrast Doppler ultrasound examinations.
Also known as energy mode.
Pulse Inversion Imaging
(PII) Pulse inversion imaging (also called phase inversion imaging) is a non-linear imaging method specifically made for enhanced detection of microbubble ultrasound contrast agents. In PII, two pulses are sent in rapid succession into the tissue; the second pulse is a mirror image of the first. The resulting echoes are added at reception. Linear scattering of the two pulses will give two echoes which are inverted copies of each other, and these echoes will therefore cancel out when added.
Linear scattering dominates in tissues. Echoes from linear scatterers such as tissue cancel, whereas those from gas microbubbles do not. Non-linear scattering of the two pulses will give two echoes which do not cancel out completely due to different bubble response to positive and negative pressures of equal magnitude. The harmonic components add, and the signal intensity difference between non-linear and linear scatterers is therefore increased. The resulting images show high sensitivity to bubbles at the resolution of a conventional image.
In harmonic imaging, the frequency range of the transmitted pulse and the received signal should not overlap, but this restriction is less in pulse inversion imaging since the transmit frequencies are not filtered out, but rather subtracted. Broader transmit and receive bandwidths are therefore allowed, giving shorter pulses and improved axial resolution, hence the alternative term wideband harmonic imaging. Many ultrasound machines offer some form of pulse inversion imaging.

See also Pulse Inversion Doppler, Narrow Bandwidth, Dead Zone, Ultrasound Phantom.
QW7437
From Sonus Pharmaceuticals
QW7437 (SonoGen) is a perfluorocarbon-based ultrasound contrast agent under development. This anionically charge-stabilized emulsion, similar to EchoGen, has been designed for echocardiographic examinations with greater safety and efficacy.
Quantison
Quantison, consisting of air-filled microbubbles with stiff and rigid human serum albumin shells, is an investigational ultrasound contrast agent for the assessment of coronary artery disease.
The stiff shell inhibits the bubbles from oscillating and decrease non-linear scattering. Quantison is capable of long lasting cavity contrast and myocardial opacification using intermittent imaging.
Drug Information and Specification
RESEARCH NAME
AIP101
DEVELOPER
Andaris Ltd. (acquired by Quadrant)
INDICATION -
DEVELOPMENT STAGE
APPLICATION
Intravenous injection
TYPE
Microbubble
Human serum albumin
CHARGE
-
Air
MICROBUBBLE SIZE
-
PREPARATION
Reconstitute with water
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]